aboutsummaryrefslogtreecommitdiff
path: root/tests/test-notify.cc
diff options
context:
space:
mode:
authorCharles Kerr <charles.kerr@canonical.com>2014-07-22 09:53:53 -0500
committerCharles Kerr <charles.kerr@canonical.com>2014-07-22 09:53:53 -0500
commit9c3d863d5e0ebe35ae69dedb5219519f0ced9339 (patch)
treedc700fa1270dadfb831ca5cf1220f9bf618cbf4d /tests/test-notify.cc
parentf5db19df10ace0919ec13f83a751cc891d8a1741 (diff)
downloadayatana-indicator-power-9c3d863d5e0ebe35ae69dedb5219519f0ced9339.tar.gz
ayatana-indicator-power-9c3d863d5e0ebe35ae69dedb5219519f0ced9339.tar.bz2
ayatana-indicator-power-9c3d863d5e0ebe35ae69dedb5219519f0ced9339.zip
copyediting: code cleanup
Diffstat (limited to 'tests/test-notify.cc')
-rw-r--r--tests/test-notify.cc163
1 files changed, 94 insertions, 69 deletions
diff --git a/tests/test-notify.cc b/tests/test-notify.cc
index d5d7e9f..74a08dc 100644
--- a/tests/test-notify.cc
+++ b/tests/test-notify.cc
@@ -81,13 +81,16 @@ protected:
GError * error = nullptr;
mock = dbus_test_dbus_mock_new(NOTIFY_BUSNAME);
- obj = dbus_test_dbus_mock_get_object(mock, NOTIFY_PATH, NOTIFY_INTERFACE, &error);
+ obj = dbus_test_dbus_mock_get_object(mock,
+ NOTIFY_PATH,
+ NOTIFY_INTERFACE,
+ &error);
g_assert_no_error (error);
dbus_test_dbus_mock_object_add_method(mock, obj, METHOD_GET_INFO,
nullptr,
G_VARIANT_TYPE("(ssss)"),
- "ret = ('mock-notify', 'test vendor', '1.0', '1.1')", // python
+ "ret = ('mock-notify', 'test vendor', '1.0', '1.1')",
&error);
g_assert_no_error (error);
@@ -142,8 +145,55 @@ TEST_F(NotifyFixture, HelloWorld)
{
}
+/***
+****
+***/
+
+
+namespace
+{
+ static constexpr double percent_critical {2.0};
+ static constexpr double percent_very_low {5.0};
+ static constexpr double percent_low {10.0};
+
+ void set_battery_percentage (IndicatorPowerDevice * battery, gdouble p)
+ {
+ g_object_set (battery, INDICATOR_POWER_DEVICE_PERCENTAGE, p, nullptr);
+ }
+}
+
+TEST_F(NotifyFixture, PercentageToLevel)
+{
+ auto battery = indicator_power_device_new ("/object/path",
+ UP_DEVICE_KIND_BATTERY,
+ 50.0,
+ UP_DEVICE_STATE_DISCHARGING,
+ 30);
+
+ // confirm that the power levels trigger at the right percentages
+ for (int i=100; i>=0; --i)
+ {
+ set_battery_percentage (battery, i);
+ const auto level = indicator_power_notifier_get_power_level(battery);
+
+ if (i <= percent_critical)
+ EXPECT_EQ (POWER_LEVEL_CRITICAL, level);
+ else if (i <= percent_very_low)
+ EXPECT_EQ (POWER_LEVEL_VERY_LOW, level);
+ else if (i <= percent_low)
+ EXPECT_EQ (POWER_LEVEL_LOW, level);
+ else
+ EXPECT_EQ (POWER_LEVEL_OK, level);
+ }
+
+ g_object_unref (battery);
+}
+
+/***
+****
+***/
-// scaffolding to listen for PropertyChanged signals and remember them
+// scaffolding to monitor PropertyChanged signals
namespace
{
enum
@@ -168,60 +218,28 @@ namespace
gpointer gchanged_params)
{
g_return_if_fail (g_variant_n_children (parameters) == 3);
- auto changed_properties = g_variant_get_child_value (parameters, 1);
- g_return_if_fail (g_variant_is_of_type (changed_properties, G_VARIANT_TYPE_DICTIONARY));
+ auto dict = g_variant_get_child_value (parameters, 1);
+ g_return_if_fail (g_variant_is_of_type (dict, G_VARIANT_TYPE_DICTIONARY));
auto changed_params = static_cast<ChangedParams*>(gchanged_params);
gint32 power_level;
- if (g_variant_lookup (changed_properties, "PowerLevel", "i", &power_level, nullptr))
+ if (g_variant_lookup (dict, "PowerLevel", "i", &power_level, nullptr))
{
changed_params->power_level = power_level;
changed_params->fields |= FIELD_POWER_LEVEL;
}
gboolean is_warning;
- if (g_variant_lookup (changed_properties, "IsWarning", "b", &is_warning, nullptr))
+ if (g_variant_lookup (dict, "IsWarning", "b", &is_warning, nullptr))
{
changed_params->is_warning = is_warning;
changed_params->fields |= FIELD_IS_WARNING;
}
- g_variant_unref (changed_properties);
+ g_variant_unref (dict);
}
-
- static const double percent_critical = 2.0;
- static const double percent_very_low = 5.0;
- static const double percent_low = 10.0;
-}
-
-TEST_F(NotifyFixture, PercentageToLevel)
-{
- auto battery = indicator_power_device_new ("/object/path",
- UP_DEVICE_KIND_BATTERY,
- 50.0,
- UP_DEVICE_STATE_DISCHARGING,
- 30);
-
- // confirm that the power levels trigger at the right percentages
- for (int i=100; i>=0; --i)
- {
- g_object_set (battery, INDICATOR_POWER_DEVICE_PERCENTAGE, (gdouble)i, nullptr);
- const auto level = indicator_power_notifier_get_power_level(battery);
-
- if (i <= percent_critical)
- EXPECT_EQ (POWER_LEVEL_CRITICAL, level);
- else if (i <= percent_very_low)
- EXPECT_EQ (POWER_LEVEL_VERY_LOW, level);
- else if (i <= percent_low)
- EXPECT_EQ (POWER_LEVEL_LOW, level);
- else
- EXPECT_EQ (POWER_LEVEL_OK, level);
- }
-
- g_object_unref (battery);
}
-
TEST_F(NotifyFixture, LevelsDuringBatteryDrain)
{
auto battery = indicator_power_device_new ("/object/path",
@@ -238,16 +256,16 @@ TEST_F(NotifyFixture, LevelsDuringBatteryDrain)
wait_msec();
ChangedParams changed_params;
- auto subscription_tag = g_dbus_connection_signal_subscribe (bus,
- nullptr,
- "org.freedesktop.DBus.Properties",
- "PropertiesChanged",
- BUS_PATH"/Battery",
- nullptr,
- G_DBUS_SIGNAL_FLAGS_NONE,
- on_battery_property_changed,
- &changed_params,
- nullptr);
+ auto sub_tag = g_dbus_connection_signal_subscribe (bus,
+ nullptr,
+ "org.freedesktop.DBus.Properties",
+ "PropertiesChanged",
+ BUS_PATH"/Battery",
+ nullptr,
+ G_DBUS_SIGNAL_FLAGS_NONE,
+ on_battery_property_changed,
+ &changed_params,
+ nullptr);
// confirm that draining the battery puts
// the power_level change through its paces
@@ -257,7 +275,7 @@ TEST_F(NotifyFixture, LevelsDuringBatteryDrain)
EXPECT_TRUE (changed_params.fields == 0);
const auto old_level = indicator_power_notifier_get_power_level(battery);
- g_object_set (battery, INDICATOR_POWER_DEVICE_PERCENTAGE, (gdouble)i, nullptr);
+ set_battery_percentage (battery, i);
const auto new_level = indicator_power_notifier_get_power_level(battery);
wait_msec();
@@ -273,20 +291,27 @@ TEST_F(NotifyFixture, LevelsDuringBatteryDrain)
}
// cleanup
- g_dbus_connection_signal_unsubscribe (bus, subscription_tag);
+ g_dbus_connection_signal_unsubscribe (bus, sub_tag);
g_object_unref (notifier);
g_object_unref (battery);
}
+/***
+****
+***/
-// confirm that notifications pop up
-// when a discharging battery's power level drops
TEST_F(NotifyFixture, EventsThatChangeNotifications)
{
// GetCapabilities returns an array containing 'actions', so that we'll
// get snap decisions and the 'IsWarning' property
GError * error = nullptr;
- dbus_test_dbus_mock_object_add_method(mock, obj, METHOD_GET_CAPS, nullptr, G_VARIANT_TYPE_STRING_ARRAY, "ret = ['actions', 'body']", &error);
+ dbus_test_dbus_mock_object_add_method (mock,
+ obj,
+ METHOD_GET_CAPS,
+ nullptr,
+ G_VARIANT_TYPE_STRING_ARRAY,
+ "ret = ['actions', 'body']",
+ &error);
g_assert_no_error (error);
auto battery = indicator_power_device_new ("/object/path",
@@ -301,16 +326,16 @@ TEST_F(NotifyFixture, EventsThatChangeNotifications)
indicator_power_notifier_set_battery (notifier, battery);
indicator_power_notifier_set_bus (notifier, bus);
ChangedParams changed_params;
- auto subscription_tag = g_dbus_connection_signal_subscribe (bus,
- nullptr,
- "org.freedesktop.DBus.Properties",
- "PropertiesChanged",
- BUS_PATH"/Battery",
- nullptr,
- G_DBUS_SIGNAL_FLAGS_NONE,
- on_battery_property_changed,
- &changed_params,
- nullptr);
+ auto sub_tag = g_dbus_connection_signal_subscribe (bus,
+ nullptr,
+ "org.freedesktop.DBus.Properties",
+ "PropertiesChanged",
+ BUS_PATH"/Battery",
+ nullptr,
+ G_DBUS_SIGNAL_FLAGS_NONE,
+ on_battery_property_changed,
+ &changed_params,
+ nullptr);
// test setup case
wait_msec();
@@ -320,7 +345,7 @@ TEST_F(NotifyFixture, EventsThatChangeNotifications)
// a) the power level changes
// b) we get a notification
changed_params = ChangedParams();
- g_object_set (battery, INDICATOR_POWER_DEVICE_PERCENTAGE, (gdouble)percent_low, nullptr);
+ set_battery_percentage (battery, percent_low);
wait_msec();
EXPECT_EQ (FIELD_POWER_LEVEL|FIELD_IS_WARNING, changed_params.fields);
EXPECT_EQ (indicator_power_notifier_get_power_level(battery), changed_params.power_level);
@@ -328,7 +353,7 @@ TEST_F(NotifyFixture, EventsThatChangeNotifications)
// now test that the warning changes if the level goes down even lower...
changed_params = ChangedParams();
- g_object_set (battery, INDICATOR_POWER_DEVICE_PERCENTAGE, (gdouble)percent_very_low, nullptr);
+ set_battery_percentage (battery, percent_very_low);
wait_msec();
EXPECT_EQ (FIELD_POWER_LEVEL, changed_params.fields);
EXPECT_EQ (POWER_LEVEL_VERY_LOW, changed_params.power_level);
@@ -349,14 +374,14 @@ TEST_F(NotifyFixture, EventsThatChangeNotifications)
// ...and that it's taken down if the power level is OK
changed_params = ChangedParams();
- g_object_set (battery, INDICATOR_POWER_DEVICE_PERCENTAGE, (gdouble)percent_low+1, nullptr);
+ set_battery_percentage (battery, percent_low+1);
wait_msec();
EXPECT_EQ (FIELD_POWER_LEVEL|FIELD_IS_WARNING, changed_params.fields);
EXPECT_EQ (POWER_LEVEL_OK, changed_params.power_level);
EXPECT_FALSE (changed_params.is_warning);
// cleanup
- g_dbus_connection_signal_unsubscribe (bus, subscription_tag);
+ g_dbus_connection_signal_unsubscribe (bus, sub_tag);
g_object_unref (notifier);
g_object_unref (battery);
}