diff options
author | Charles Kerr <charles.kerr@canonical.com> | 2014-07-22 09:53:53 -0500 |
---|---|---|
committer | Charles Kerr <charles.kerr@canonical.com> | 2014-07-22 09:53:53 -0500 |
commit | 9c3d863d5e0ebe35ae69dedb5219519f0ced9339 (patch) | |
tree | dc700fa1270dadfb831ca5cf1220f9bf618cbf4d /tests/test-notify.cc | |
parent | f5db19df10ace0919ec13f83a751cc891d8a1741 (diff) | |
download | ayatana-indicator-power-9c3d863d5e0ebe35ae69dedb5219519f0ced9339.tar.gz ayatana-indicator-power-9c3d863d5e0ebe35ae69dedb5219519f0ced9339.tar.bz2 ayatana-indicator-power-9c3d863d5e0ebe35ae69dedb5219519f0ced9339.zip |
copyediting: code cleanup
Diffstat (limited to 'tests/test-notify.cc')
-rw-r--r-- | tests/test-notify.cc | 163 |
1 files changed, 94 insertions, 69 deletions
diff --git a/tests/test-notify.cc b/tests/test-notify.cc index d5d7e9f..74a08dc 100644 --- a/tests/test-notify.cc +++ b/tests/test-notify.cc @@ -81,13 +81,16 @@ protected: GError * error = nullptr; mock = dbus_test_dbus_mock_new(NOTIFY_BUSNAME); - obj = dbus_test_dbus_mock_get_object(mock, NOTIFY_PATH, NOTIFY_INTERFACE, &error); + obj = dbus_test_dbus_mock_get_object(mock, + NOTIFY_PATH, + NOTIFY_INTERFACE, + &error); g_assert_no_error (error); dbus_test_dbus_mock_object_add_method(mock, obj, METHOD_GET_INFO, nullptr, G_VARIANT_TYPE("(ssss)"), - "ret = ('mock-notify', 'test vendor', '1.0', '1.1')", // python + "ret = ('mock-notify', 'test vendor', '1.0', '1.1')", &error); g_assert_no_error (error); @@ -142,8 +145,55 @@ TEST_F(NotifyFixture, HelloWorld) { } +/*** +**** +***/ + + +namespace +{ + static constexpr double percent_critical {2.0}; + static constexpr double percent_very_low {5.0}; + static constexpr double percent_low {10.0}; + + void set_battery_percentage (IndicatorPowerDevice * battery, gdouble p) + { + g_object_set (battery, INDICATOR_POWER_DEVICE_PERCENTAGE, p, nullptr); + } +} + +TEST_F(NotifyFixture, PercentageToLevel) +{ + auto battery = indicator_power_device_new ("/object/path", + UP_DEVICE_KIND_BATTERY, + 50.0, + UP_DEVICE_STATE_DISCHARGING, + 30); + + // confirm that the power levels trigger at the right percentages + for (int i=100; i>=0; --i) + { + set_battery_percentage (battery, i); + const auto level = indicator_power_notifier_get_power_level(battery); + + if (i <= percent_critical) + EXPECT_EQ (POWER_LEVEL_CRITICAL, level); + else if (i <= percent_very_low) + EXPECT_EQ (POWER_LEVEL_VERY_LOW, level); + else if (i <= percent_low) + EXPECT_EQ (POWER_LEVEL_LOW, level); + else + EXPECT_EQ (POWER_LEVEL_OK, level); + } + + g_object_unref (battery); +} + +/*** +**** +***/ -// scaffolding to listen for PropertyChanged signals and remember them +// scaffolding to monitor PropertyChanged signals namespace { enum @@ -168,60 +218,28 @@ namespace gpointer gchanged_params) { g_return_if_fail (g_variant_n_children (parameters) == 3); - auto changed_properties = g_variant_get_child_value (parameters, 1); - g_return_if_fail (g_variant_is_of_type (changed_properties, G_VARIANT_TYPE_DICTIONARY)); + auto dict = g_variant_get_child_value (parameters, 1); + g_return_if_fail (g_variant_is_of_type (dict, G_VARIANT_TYPE_DICTIONARY)); auto changed_params = static_cast<ChangedParams*>(gchanged_params); gint32 power_level; - if (g_variant_lookup (changed_properties, "PowerLevel", "i", &power_level, nullptr)) + if (g_variant_lookup (dict, "PowerLevel", "i", &power_level, nullptr)) { changed_params->power_level = power_level; changed_params->fields |= FIELD_POWER_LEVEL; } gboolean is_warning; - if (g_variant_lookup (changed_properties, "IsWarning", "b", &is_warning, nullptr)) + if (g_variant_lookup (dict, "IsWarning", "b", &is_warning, nullptr)) { changed_params->is_warning = is_warning; changed_params->fields |= FIELD_IS_WARNING; } - g_variant_unref (changed_properties); + g_variant_unref (dict); } - - static const double percent_critical = 2.0; - static const double percent_very_low = 5.0; - static const double percent_low = 10.0; -} - -TEST_F(NotifyFixture, PercentageToLevel) -{ - auto battery = indicator_power_device_new ("/object/path", - UP_DEVICE_KIND_BATTERY, - 50.0, - UP_DEVICE_STATE_DISCHARGING, - 30); - - // confirm that the power levels trigger at the right percentages - for (int i=100; i>=0; --i) - { - g_object_set (battery, INDICATOR_POWER_DEVICE_PERCENTAGE, (gdouble)i, nullptr); - const auto level = indicator_power_notifier_get_power_level(battery); - - if (i <= percent_critical) - EXPECT_EQ (POWER_LEVEL_CRITICAL, level); - else if (i <= percent_very_low) - EXPECT_EQ (POWER_LEVEL_VERY_LOW, level); - else if (i <= percent_low) - EXPECT_EQ (POWER_LEVEL_LOW, level); - else - EXPECT_EQ (POWER_LEVEL_OK, level); - } - - g_object_unref (battery); } - TEST_F(NotifyFixture, LevelsDuringBatteryDrain) { auto battery = indicator_power_device_new ("/object/path", @@ -238,16 +256,16 @@ TEST_F(NotifyFixture, LevelsDuringBatteryDrain) wait_msec(); ChangedParams changed_params; - auto subscription_tag = g_dbus_connection_signal_subscribe (bus, - nullptr, - "org.freedesktop.DBus.Properties", - "PropertiesChanged", - BUS_PATH"/Battery", - nullptr, - G_DBUS_SIGNAL_FLAGS_NONE, - on_battery_property_changed, - &changed_params, - nullptr); + auto sub_tag = g_dbus_connection_signal_subscribe (bus, + nullptr, + "org.freedesktop.DBus.Properties", + "PropertiesChanged", + BUS_PATH"/Battery", + nullptr, + G_DBUS_SIGNAL_FLAGS_NONE, + on_battery_property_changed, + &changed_params, + nullptr); // confirm that draining the battery puts // the power_level change through its paces @@ -257,7 +275,7 @@ TEST_F(NotifyFixture, LevelsDuringBatteryDrain) EXPECT_TRUE (changed_params.fields == 0); const auto old_level = indicator_power_notifier_get_power_level(battery); - g_object_set (battery, INDICATOR_POWER_DEVICE_PERCENTAGE, (gdouble)i, nullptr); + set_battery_percentage (battery, i); const auto new_level = indicator_power_notifier_get_power_level(battery); wait_msec(); @@ -273,20 +291,27 @@ TEST_F(NotifyFixture, LevelsDuringBatteryDrain) } // cleanup - g_dbus_connection_signal_unsubscribe (bus, subscription_tag); + g_dbus_connection_signal_unsubscribe (bus, sub_tag); g_object_unref (notifier); g_object_unref (battery); } +/*** +**** +***/ -// confirm that notifications pop up -// when a discharging battery's power level drops TEST_F(NotifyFixture, EventsThatChangeNotifications) { // GetCapabilities returns an array containing 'actions', so that we'll // get snap decisions and the 'IsWarning' property GError * error = nullptr; - dbus_test_dbus_mock_object_add_method(mock, obj, METHOD_GET_CAPS, nullptr, G_VARIANT_TYPE_STRING_ARRAY, "ret = ['actions', 'body']", &error); + dbus_test_dbus_mock_object_add_method (mock, + obj, + METHOD_GET_CAPS, + nullptr, + G_VARIANT_TYPE_STRING_ARRAY, + "ret = ['actions', 'body']", + &error); g_assert_no_error (error); auto battery = indicator_power_device_new ("/object/path", @@ -301,16 +326,16 @@ TEST_F(NotifyFixture, EventsThatChangeNotifications) indicator_power_notifier_set_battery (notifier, battery); indicator_power_notifier_set_bus (notifier, bus); ChangedParams changed_params; - auto subscription_tag = g_dbus_connection_signal_subscribe (bus, - nullptr, - "org.freedesktop.DBus.Properties", - "PropertiesChanged", - BUS_PATH"/Battery", - nullptr, - G_DBUS_SIGNAL_FLAGS_NONE, - on_battery_property_changed, - &changed_params, - nullptr); + auto sub_tag = g_dbus_connection_signal_subscribe (bus, + nullptr, + "org.freedesktop.DBus.Properties", + "PropertiesChanged", + BUS_PATH"/Battery", + nullptr, + G_DBUS_SIGNAL_FLAGS_NONE, + on_battery_property_changed, + &changed_params, + nullptr); // test setup case wait_msec(); @@ -320,7 +345,7 @@ TEST_F(NotifyFixture, EventsThatChangeNotifications) // a) the power level changes // b) we get a notification changed_params = ChangedParams(); - g_object_set (battery, INDICATOR_POWER_DEVICE_PERCENTAGE, (gdouble)percent_low, nullptr); + set_battery_percentage (battery, percent_low); wait_msec(); EXPECT_EQ (FIELD_POWER_LEVEL|FIELD_IS_WARNING, changed_params.fields); EXPECT_EQ (indicator_power_notifier_get_power_level(battery), changed_params.power_level); @@ -328,7 +353,7 @@ TEST_F(NotifyFixture, EventsThatChangeNotifications) // now test that the warning changes if the level goes down even lower... changed_params = ChangedParams(); - g_object_set (battery, INDICATOR_POWER_DEVICE_PERCENTAGE, (gdouble)percent_very_low, nullptr); + set_battery_percentage (battery, percent_very_low); wait_msec(); EXPECT_EQ (FIELD_POWER_LEVEL, changed_params.fields); EXPECT_EQ (POWER_LEVEL_VERY_LOW, changed_params.power_level); @@ -349,14 +374,14 @@ TEST_F(NotifyFixture, EventsThatChangeNotifications) // ...and that it's taken down if the power level is OK changed_params = ChangedParams(); - g_object_set (battery, INDICATOR_POWER_DEVICE_PERCENTAGE, (gdouble)percent_low+1, nullptr); + set_battery_percentage (battery, percent_low+1); wait_msec(); EXPECT_EQ (FIELD_POWER_LEVEL|FIELD_IS_WARNING, changed_params.fields); EXPECT_EQ (POWER_LEVEL_OK, changed_params.power_level); EXPECT_FALSE (changed_params.is_warning); // cleanup - g_dbus_connection_signal_unsubscribe (bus, subscription_tag); + g_dbus_connection_signal_unsubscribe (bus, sub_tag); g_object_unref (notifier); g_object_unref (battery); } |