diff options
Diffstat (limited to 'src/org.freedesktop.UPower.Device.xml')
-rw-r--r-- | src/org.freedesktop.UPower.Device.xml | 705 |
1 files changed, 0 insertions, 705 deletions
diff --git a/src/org.freedesktop.UPower.Device.xml b/src/org.freedesktop.UPower.Device.xml deleted file mode 100644 index 7c9a65b..0000000 --- a/src/org.freedesktop.UPower.Device.xml +++ /dev/null @@ -1,705 +0,0 @@ -<!DOCTYPE node PUBLIC -"-//freedesktop//DTD D-BUS Object Introspection 1.0//EN" -"http://www.freedesktop.org/standards/dbus/1.0/introspect.dtd" [ - <!ENTITY ERROR_GENERAL "org.freedesktop.UPower.Device.GeneralError"> -]> -<node name="/" xmlns:doc="http://www.freedesktop.org/dbus/1.0/doc.dtd"> - <interface name="org.freedesktop.UPower.Device"> - <doc:doc> - <doc:description> - <doc:para> - Objects implementing this interface are usually discovered through - the <doc:tt>org.freedesktop.UPower</doc:tt> interface on - the <doc:tt>/org/freedesktop/UPower</doc:tt> object on - the D-Bus system bus service with the well-known - name <doc:tt>org.freedesktop.UPower</doc:tt> using - the - <doc:ref type="method" to="Power.EnumerateDevices">EnumerateDevices</doc:ref> - method. - </doc:para> - <doc:para> - <doc:example language="shell" title="simple example"> - <doc:code> -$ dbus-send --print-reply \ - --system \ - --dest=org.freedesktop.UPower \ - /org/freedesktop/UPower/devices/battery_BAT0 \ - org.freedesktop.DBus.Properties.GetAll \ - string:org.freedesktop.UPower.Device - -method return sender=:1.386 -> dest=:1.477 reply_serial=2 - array [ - dict entry( - string "native-path" - variant string "/sys/devices/LNXSYSTM:00/device:00/PNP0A08:00/device:01/PNP0C09:00/PNP0C0A:00/power_supply/BAT0" - ) - dict entry( - string "vendor" - variant string "SONY" - ) - dict entry( - string "model" - variant string "42T4568" - ) - dict entry( - string "serial" - variant string "4179" - ) - dict entry( - string "update-time" - variant uint64 1226417875 - ) - dict entry( - string "type" - variant uint 2 - ) - dict entry( - string "power-supply" - variant boolean true - ) - dict entry( - string "has-history" - variant boolean true - ) - dict entry( - string "has-statistics" - variant boolean true - ) - dict entry( - string "online" - variant boolean false - ) - dict entry( - string "energy" - variant double 72.85 - ) - dict entry( - string "energy-empty" - variant double 0 - ) - dict entry( - string "energy-full" - variant double 74.55 - ) - dict entry( - string "energy-full-design" - variant double 74.88 - ) - dict entry( - string "energy-rate" - variant double 0 - ) - dict entry( - string "voltage" - variant double 16.415 - ) - dict entry( - string "time-to-empty" - variant int64 0 - ) - dict entry( - string "time-to-full" - variant int64 0 - ) - dict entry( - string "percentage" - variant double 97.7197 - ) - dict entry( - string "is-present" - variant boolean true - ) - dict entry( - string "state" - variant uint 3 - ) - dict entry( - string "is-rechargeable" - variant boolean true - ) - dict entry( - string "capacity" - variant double 100 - ) - dict entry( - string "technology" - variant uint 1 - ) - ] - </doc:code> - </doc:example> - </doc:para> - <doc:para> - Unless otherwise noted, an empty string or the value 0 in a - property on this interface means not set. - </doc:para> - </doc:description> - </doc:doc> - - - <!-- ************************************************************ --> - <method name="Refresh"> - <annotation name="org.freedesktop.DBus.GLib.Async" value=""/> - <doc:doc> - <doc:description> - <doc:para> - Refreshes the data collected from the power source. - </doc:para> - </doc:description> - <doc:permission>Callers need the org.freedesktop.upower.refresh-power-source authorization</doc:permission> - <doc:errors> - <doc:error name="&ERROR_GENERAL;">if an error occured while refreshing</doc:error> - </doc:errors> - </doc:doc> - </method> - - <!-- ************************************************************ --> - <signal name="Changed"> - <doc:doc> - <doc:description> - <doc:para> - Some value on the power source changed. - </doc:para> - </doc:description> - </doc:doc> - </signal> - - <!-- ************************************************************ --> - <method name="GetHistory"> - <annotation name="org.freedesktop.DBus.GLib.Async" value=""/> - <arg name="type" direction="in" type="s"> - <doc:doc><doc:summary>The type of history. - Valid types are <doc:tt>rate</doc:tt> or <doc:tt>charge</doc:tt>.</doc:summary></doc:doc> - </arg> - <arg name="timespan" direction="in" type="u"> - <doc:doc><doc:summary>The amount of data to return in seconds, or 0 for all.</doc:summary></doc:doc> - </arg> - <arg name="resolution" direction="in" type="u"> - <doc:doc> - <doc:summary> - The approximate number of points to return. - A higher resolution is more accurate, at the expense of plotting speed. - </doc:summary> - </doc:doc> - </arg> - <arg name="data" direction="out" type="a(udu)"> - <doc:doc><doc:summary> - The history data for the power device, if the device supports history. - Data is ordered from the earliest in time, to the newest data point. - Each element contains the following members: - <doc:list> - <doc:item> - <doc:term>time</doc:term> - <doc:definition> - The time value in seconds from the <doc:tt>gettimeofday()</doc:tt> method. - </doc:definition> - </doc:item> - <doc:item> - <doc:term>value</doc:term> - <doc:definition> - The data value, for instance the rate in W or the charge in %. - </doc:definition> - </doc:item> - <doc:item> - <doc:term>state</doc:term> - <doc:definition> - The state of the device, for instance <doc:tt>charging</doc:tt> or - <doc:tt>discharging</doc:tt>. - </doc:definition> - </doc:item> - </doc:list> - </doc:summary></doc:doc> - </arg> - <doc:doc> - <doc:description> - <doc:para> - Gets history for the power device that is persistent across reboots. - </doc:para> - </doc:description> - </doc:doc> - </method> - - <!-- ************************************************************ --> - <method name="GetStatistics"> - <annotation name="org.freedesktop.DBus.GLib.Async" value=""/> - <arg name="type" direction="in" type="s"> - <doc:doc><doc:summary>The mode for the statistics. - Valid types are <doc:tt>charging</doc:tt> or <doc:tt>discharging</doc:tt>.</doc:summary></doc:doc> - </arg> - <arg name="data" direction="out" type="a(dd)"> - <doc:doc><doc:summary> - The statistics data for the power device. - Each element contains the following members: - <doc:list> - <doc:item> - <doc:term>value</doc:term> - <doc:definition> - The value of the percentage point, usually in seconds - </doc:definition> - </doc:item> - <doc:item> - <doc:term>accuracy</doc:term> - <doc:definition> - The accuracy of the prediction in percent. - </doc:definition> - </doc:item> - </doc:list> - </doc:summary></doc:doc> - </arg> - <doc:doc> - <doc:description> - <doc:para> - Gets statistics for the power device that may be interesting - to show on a graph in the session. - </doc:para> - </doc:description> - </doc:doc> - </method> - - <!-- ************************************************************ --> - <property name="NativePath" type="s" access="read"> - <doc:doc> - <doc:description> - <doc:para> - OS specific native path of the power source. On Linux this - is the sysfs path, for - example <doc:tt>/sys/devices/LNXSYSTM:00/device:00/PNP0C0A:00/power_supply/BAT0</doc:tt>. Is - blank if the device is being driven by a user space - driver. - </doc:para> - </doc:description> - </doc:doc> - </property> - - <property name="Vendor" type="s" access="read"> - <doc:doc> - <doc:description> - <doc:para> - Name of the vendor of the battery. - </doc:para> - </doc:description> - </doc:doc> - </property> - - <property name="Model" type="s" access="read"> - <doc:doc> - <doc:description> - <doc:para> - Name of the model of this battery. - </doc:para> - </doc:description> - </doc:doc> - </property> - - <property name="Serial" type="s" access="read"> - <doc:doc> - <doc:description> - <doc:para> - Unique serial number of the battery. - </doc:para> - </doc:description> - </doc:doc> - </property> - - <property name="UpdateTime" type="t" access="read"> - <doc:doc> - <doc:description> - <doc:para> - The point in time (seconds since the Epoch Jan 1, 1970 - 0:00 UTC) that data was read from the power source. - </doc:para> - </doc:description> - </doc:doc> - </property> - - <property name="Type" type="u" access="read"> - <doc:doc> - <doc:description> - <doc:para> - Type of power source. - </doc:para> - <doc:list> - <doc:item> - <doc:term>0</doc:term><doc:definition>Unknown</doc:definition> - </doc:item> - <doc:item> - <doc:term>1</doc:term><doc:definition>Line Power</doc:definition> - </doc:item> - <doc:item> - <doc:term>2</doc:term><doc:definition>Battery</doc:definition> - </doc:item> - <doc:item> - <doc:term>3</doc:term><doc:definition>Ups</doc:definition> - </doc:item> - <doc:item> - <doc:term>4</doc:term><doc:definition>Monitor</doc:definition> - </doc:item> - <doc:item> - <doc:term>5</doc:term><doc:definition>Mouse</doc:definition> - </doc:item> - <doc:item> - <doc:term>6</doc:term><doc:definition>Keyboard</doc:definition> - </doc:item> - <doc:item> - <doc:term>7</doc:term><doc:definition>Pda</doc:definition> - </doc:item> - <doc:item> - <doc:term>8</doc:term><doc:definition>Phone</doc:definition> - </doc:item> - </doc:list> - </doc:description> - </doc:doc> - </property> - - <property name="PowerSupply" type="b" access="read"> - <doc:doc> - <doc:description> - <doc:para> - If the power device is used to supply the system. - This would be set TRUE for laptop batteries and UPS devices, - but set FALSE for wireless mice or PDAs. - </doc:para> - </doc:description> - </doc:doc> - </property> - - <property name="HasHistory" type="b" access="read"> - <doc:doc> - <doc:description> - <doc:para> - If the power device has history. - </doc:para> - </doc:description> - </doc:doc> - </property> - - <property name="HasStatistics" type="b" access="read"> - <doc:doc> - <doc:description> - <doc:para> - If the power device has statistics. - </doc:para> - </doc:description> - </doc:doc> - </property> - - <property name="Online" type="b" access="read"> - <doc:doc> - <doc:description> - <doc:para> - Whether power is currently being provided through line power. - This property is only valid if the property - <doc:ref type="property" to="Source:Type">type</doc:ref> - has the value "line-power". - </doc:para> - </doc:description> - </doc:doc> - </property> - - <property name="Energy" type="d" access="read"> - <doc:doc> - <doc:description> - <doc:para> - Amount of energy (measured in Wh) currently available in - the power source. - </doc:para><doc:para> - This property is only valid if the property - <doc:ref type="property" to="Source:Type">type</doc:ref> - has the value "battery". - </doc:para> - </doc:description> - </doc:doc> - </property> - - <property name="EnergyEmpty" type="d" access="read"> - <doc:doc> - <doc:description> - <doc:para> - Amount of energy (measured in Wh) in the power source when - it's considered to be empty. - </doc:para><doc:para> - This property is only valid if the property - <doc:ref type="property" to="Source:Type">type</doc:ref> - has the value "battery". - </doc:para> - </doc:description> - </doc:doc> - </property> - - <property name="EnergyFull" type="d" access="read"> - <doc:doc> - <doc:description> - <doc:para> - Amount of energy (measured in Wh) in the power source when - it's considered full. - </doc:para><doc:para> - This property is only valid if the property - <doc:ref type="property" to="Source:Type">type</doc:ref> - has the value "battery". - </doc:para> - </doc:description> - </doc:doc> - </property> - - <property name="EnergyFullDesign" type="d" access="read"> - <doc:doc> - <doc:description> - <doc:para> - Amount of energy (measured in Wh) the power source is - designed to hold when it's considered full. - </doc:para><doc:para> - This property is only valid if the property - <doc:ref type="property" to="Source:Type">type</doc:ref> - has the value "battery". - </doc:para> - </doc:description> - </doc:doc> - </property> - - <property name="EnergyRate" type="d" access="read"> - <doc:doc> - <doc:description> - <doc:para> - Amount of energy being drained from the source, measured - in W. If positive, the source is being discharged, if - negative it's being charged. - </doc:para><doc:para> - This property is only valid if the property - <doc:ref type="property" to="Source:Type">type</doc:ref> - has the value "battery". - </doc:para> - </doc:description> - </doc:doc> - </property> - - <property name="Voltage" type="d" access="read"> - <doc:doc> - <doc:description> - <doc:para> - Voltage in the Cell or being recorded by the meter. - </doc:para> - </doc:description> - </doc:doc> - </property> - - <property name="TimeToEmpty" type="x" access="read"> - <doc:doc> - <doc:description> - <doc:para> - Number of seconds until the power source is considered empty. - Is set to 0 if unknown. - </doc:para><doc:para> - This property is only valid if the property - <doc:ref type="property" to="Source:Type">type</doc:ref> - has the value "battery". - </doc:para> - </doc:description> - </doc:doc> - </property> - - <property name="TimeToFull" type="x" access="read"> - <doc:doc> - <doc:description> - <doc:para> - Number of seconds until the power source is considered full. - Is set to 0 if unknown. - </doc:para><doc:para> - This property is only valid if the property - <doc:ref type="property" to="Source:Type">type</doc:ref> - has the value "battery". - </doc:para> - </doc:description> - </doc:doc> - </property> - - <property name="Percentage" type="d" access="read"> - <doc:doc> - <doc:description> - <doc:para> - The amount of energy left in the power source expressed as - a percentage between 0 and 100. Typically this is the same as - (<doc:ref type="property" to="Source:Energy">energy</doc:ref> - - <doc:ref type="property" to="Source:EnergyEmpty">energy-empty</doc:ref>) / - (<doc:ref type="property" to="Source:EnergyFull">energy-full</doc:ref> - - <doc:ref type="property" to="Source:EnergyEmpty">energy-empty</doc:ref>). - However, some primitive power sources are capable of only - reporting percentages and in this case the energy-* - properties will be unset while this property is set. - </doc:para><doc:para> - This property is only valid if the property - <doc:ref type="property" to="Source:Type">type</doc:ref> - has the value "battery". - </doc:para> - </doc:description> - </doc:doc> - </property> - - <property name="IsPresent" type="b" access="read"> - <doc:doc> - <doc:description> - <doc:para> - If the power source is present in the bay. - This field is required as some batteries are hot-removable, for example - expensive UPS and most laptop batteries. - </doc:para><doc:para> - This property is only valid if the property - <doc:ref type="property" to="Source:Type">type</doc:ref> - has the value "battery". - </doc:para> - </doc:description> - </doc:doc> - </property> - - <property name="State" type="u" access="read"> - <doc:doc> - <doc:description> - <doc:para> - The battery power state. - </doc:para> - <doc:list> - <doc:item> - <doc:term>0</doc:term><doc:definition>Unknown</doc:definition> - </doc:item> - <doc:item> - <doc:term>1</doc:term><doc:definition>Charging</doc:definition> - </doc:item> - <doc:item> - <doc:term>2</doc:term><doc:definition>Discharging</doc:definition> - </doc:item> - <doc:item> - <doc:term>3</doc:term><doc:definition>Empty</doc:definition> - </doc:item> - <doc:item> - <doc:term>4</doc:term><doc:definition>Fully charged</doc:definition> - </doc:item> - <doc:item> - <doc:term>5</doc:term><doc:definition>Pending charge</doc:definition> - </doc:item> - <doc:item> - <doc:term>6</doc:term><doc:definition>Pending discharge</doc:definition> - </doc:item> - </doc:list> - <doc:para> - This property is only valid if the property - <doc:ref type="property" to="Source:Type">type</doc:ref> - has the value "battery". - </doc:para> - </doc:description> - </doc:doc> - </property> - - <property name="IsRechargeable" type="b" access="read"> - <doc:doc> - <doc:description> - <doc:para> - If the power source is rechargeable. - </doc:para><doc:para> - This property is only valid if the property - <doc:ref type="property" to="Source:Type">type</doc:ref> - has the value "battery". - </doc:para> - </doc:description> - </doc:doc> - </property> - - <property name="Capacity" type="d" access="read"> - <doc:doc> - <doc:description> - <doc:para> - The capacity of the power source expressed as a percentage between 0 and 100. - The capacity of the battery will reduce with age. - A capacity value less than 75% is usually a sign that you should renew your battery. - Typically this value is the same as - (<doc:ref type="property" to="Source:FullDesign">full-design</doc:ref> / - <doc:ref type="property" to="Source:Full">full</doc:ref>) * 100. - However, some primitive power sources are not capable reporting capacity - and in this case the capacity property will be unset. - </doc:para><doc:para> - This property is only valid if the property - <doc:ref type="property" to="Source:Type">type</doc:ref> - has the value "battery". - </doc:para> - </doc:description> - </doc:doc> - </property> - - <property name="Technology" type="u" access="read"> - <doc:doc> - <doc:description> - <doc:para> - Technology used in the battery: - </doc:para> - <doc:list> - <doc:item> - <doc:term>0</doc:term><doc:definition>Unknown</doc:definition> - </doc:item> - <doc:item> - <doc:term>1</doc:term><doc:definition>Lithium ion</doc:definition> - </doc:item> - <doc:item> - <doc:term>2</doc:term><doc:definition>Lithium polymer</doc:definition> - </doc:item> - <doc:item> - <doc:term>3</doc:term><doc:definition>Lithium iron phosphate</doc:definition> - </doc:item> - <doc:item> - <doc:term>4</doc:term><doc:definition>Lead acid</doc:definition> - </doc:item> - <doc:item> - <doc:term>5</doc:term><doc:definition>Nickel cadmium</doc:definition> - </doc:item> - <doc:item> - <doc:term>6</doc:term><doc:definition>Nickel metal hydride</doc:definition> - </doc:item> - </doc:list> - <doc:para> - This property is only valid if the property - <doc:ref type="property" to="Source:Type">type</doc:ref> - has the value "battery". - </doc:para> - </doc:description> - </doc:doc> - </property> - - <property name="RecallNotice" type="b" access="read"> - <doc:doc> - <doc:description> - <doc:para> - If the device may have been recalled by the vendor due to a suspected - fault. - This key does not imply the device is faulty, only that it approximatly - matches the description from the vendor of units that were recalled. - </doc:para> - </doc:description> - </doc:doc> - </property> - - <property name="RecallVendor" type="s" access="read"> - <doc:doc> - <doc:description> - <doc:para> - The vendor that is handling the hardware recall. - </doc:para> - <doc:para> - This property is only valid if the property recall-notice is true. - </doc:para> - </doc:description> - </doc:doc> - </property> - - <property name="RecallUrl" type="s" access="read"> - <doc:doc> - <doc:description> - <doc:para> - The URL to visit about the hardware recall. - </doc:para> - <doc:para> - This property is only valid if the property recall-notice is true. - </doc:para> - </doc:description> - </doc:doc> - </property> - - </interface> - -</node> |